E15 Stepper Connection Error

Follow these steps to check cable connections to the arm board (located inside the tower on the lower left wall)

Step 1: Check that assembly related cables are connected

  1. Cable connection to Lift motor

  2. Cable connections to Arm 1 connector panel

  3. Cable connections to power strip

  4. Restart the system. If the error persists, continue to the next step.

Step 2: Check the status light on the motors

  1. If the lift motor and elbow motor lights are both green, skip to Step 4.

  2. If either motor light is off, move on to Step 3

Step 3: Check connections to the power board

remove the front panel of the tower to check internal connections:

  1. If the info light is Orange for the power supply, check the cable #1 and cable #18.

  2. If power supply status light is Green, but the error persists, continue to check the power board connections as shown in the photo diagram:

    1. Cable #6, #8, #10, #18 (2 different connections), and Cable #26. Make sure all are plugged all the way in and no wires or pins are loose.

    2. If the green light is not on, check cable #18 (the smaller one at the back of the board)

Step 4: Check connections to the arm board

Remove the front panel of the tower to check internal connections:

  1. Check #7, #9, #12, #26, and #28. Make sure all are plugged all the way in and no wires or pins are loose.

  2. Check that the small red jumper is connected as shown in the photo.

  • If no lights are on, check cable #26 connection.

  • If only 3x Green LEDs are on, check connections to power supplies.

  • If only 3x Orange LEDs are on, check connections to each motor.

  • If all 3x Orange LEDs are on AND any neighboring Green LEDs are on:

    • If the first 3x Green LEDs are on, check Cable #7 connection to the arm board and cable #6 to the power board.

    • If 2x Green LEDs are on, check Cable #9 connection to the arm board and cable #8 to the power board.

    • If 1x Green LEDs are on, check Cable #12 connection to the arm board and cable #10 to the power board.

  • If there are 5 orange and 5 green lights on, check that the small red jumper is connected.

Step 5: Unplug the robot

If all internal connections, external assembly connections, and status lights are good, turn off the power and unplug the power cord to the robot. Leave it off and unplugged for AT LEAST 2 MINUTES. Then, plug it in and turn the power back on.

Did this answer your question?